International Communications in Heat and Mass Transfer, Volume 39, Issue 9, November 2012, Pages 1375-1383
H.A. Mohammed, K. Narrein
Department of Thermofluids, Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, 81310 UTM Skudai, Johor Bahru, Malaysia
Abstract
The effects of using different geometrical parameters with the combination of nanofluid on heat transfer and fluid flow characteristics in a helically coiled tube heat exchanger (HCTHE) are numerically investigated. A CuO nanoparticle with a diameter of 25 nm dispersed in water with a particle concentration of 4% was used as the working fluid. The three dimensional governing equations (continuity, momentum and energy) along with the boundary conditions are solved using the finite volume method (FVM). The mass flow rate of water in the annulus was kept constant and the nanofluid flow rate in the inner tube was varied. The effect of flow configuration (parallel and counter) was also examined in this study. The performance of the HCTHE was evaluated in terms of Nusselt number, heat transfer rate, pressure drop, effectiveness and performance index. The results reveal that certain geometrical parameters such as the helix radius and inner tube diameter do affect the performance of the HCTHE under laminar flow conditions. It is also found that counter-flow configuration produced better results as compared to parallel-flow configuration.