Annals of Nuclear Energy, Volume 68, June 2014, Pages 118-123 .
Xingjie Peng a,b Kan Wanga, Qing Lib
a-Department of Engineering Physics, Tsinghua University, Beijing, China and
b-Science and Technology on Reactor System Design Technology Laboratory, Nuclear Power Institute of China, Chengdu, China.
Abstract
The Ordinary Kriging (OK) method is presented that is designed for a core power mapping calculation of pressurized water reactors (PWRs). Measurements from DayaBay Unit 1 PWR are used to verify the accuracy of the OK method. The root mean square (RMS) reconstruction errors are kept at less than 0.35%, and the maximum reconstruction relative errors (RE) are kept at less than 1.02% for the entire operating cycle. The reconstructed assembly power distribution results show that the OK method is fit for core power distribution monitoring. The quality of power distribution obtained by the OK method is partly determined by the neutron detector locations, and the OK method is also applied to solve the optimal neutron detector location problem. The spatially averaged ordinary kriging variance (AOKV) is minimized using simulated annealing, and then, the optimal in-core neutron detector locations are obtained. The result shows that the current neutron detector location of DayaBay Unit 1 reactor is near-optimal.
Advances in Engineering Advances in Engineering features breaking research judged by Advances in Engineering advisory team to be of key importance in the Engineering field. Papers are selected from over 10,000 published each week from most peer reviewed journals.